| sponsored by |
|
|
| Tensile Stress in Bolt | Usual | Severe | Root | |
Tensile Stress Area: | 0.142 | 0.137 | 0.126 | sq.in. |
| Tensile Stress due to Preload: | 30,000 | 30,000 | 30,000 | p.s.i. |
Tensile Stress due to Static Load: | 0 | 0 | 0 | p.s.i. |
Tensile Stress Sum: | 30,000 | 30,000 | 30,000 | p.s.i. |
Preload: | 4,257 | 4,104 | 3,771 | pounds |
| Torque Required to Induce Preload: | 35.475 425.699 |
34.202 410.426 |
31.428 377.131 |
ft-lbs in-lbs |
| Engagement to Protect Bolt Thread: | 0.386 5.02 | 0.373 4.84 | 0.342 4.45 | inches ×pitch |
| Engagement to Protect Nut Thread: | 0.257 3.34 | 0.247 3.22 |
0.227 2.96 |
inches ×pitch |
| Bolt Thread Shear Stress | ||||
| Bolt Thread Shear Stress Area: | 0.735 | 0.735 | 0.735 | sq.in. |
| Stress due to Preload: | 5,796 | 5,588 | 5,134 | p.s.i. |
| Stress due to Static Load: | 0 | 0 | 0 | p.s.i. |
| Bolt Thread Shear Stress Sum: | 5,796 | 5,588 | 5,134 | p.s.i. |
| Nut Thread Shear Stress | ||||
| Nut Thread Shear Stress Area: | 1.106 | 1.106 | 1.106 | sq.in. |
| Stress due to Preload: | 3,850 | 3,711 | 3,410 | p.s.i. |
| Stress due to Static Load: | 0 | 0 | 0 | p.s.i. |
| Nut Thread Shear Stress Sum: | 3,850 | 3,711 | 3,410 | p.s.i. |
| Allowance: 0.0015 inches | Pitch: 0.0769 inches |
| Bolt | Nut | ||
| Minimum Maximum Tolerance | Minimum Maximum Tolerance | ||
Major Diameter: | 0.4877 - 0.4985 (0.0109) | 0.5000 - 0.5192* ( ) inches | |
Pitch Diameter: | 0.4423 - 0.4485 (0.0062) | 0.4500 - 0.4581 (0.0081) inches | |
Minor Diameter: | 0.3924*- 0.4152 ( ) | 0.4167 - 0.4378 (0.0211) inches | |
| * No official specification exists. | ||